1.Introduction

In order to stop global warming (reduce CO2 gas), it is required to follow the Energy Saving Law which has been revised recently. Reduction of the use of energy is mandatory by all industries, without allowing a sanctuary, including railway transportation industry.
HITACHI has been developing Regenerative Power Absorption Unit to prevent regenerative cancelled during braking of a train. In order to prevent the feeder power from dropping as well as achieving the purposes of stopping global warming and saving energy, HITACHI has developed the B-Chop (Energy Storage for Traction Power Supply System) to utilize the re-generative power.

2.Characteristic

Figure of Stray Current Monitoring System

3.Rating and Specifications

DC750/600V
No. Rated
Voltage (V)*1
Rated
Capacity (kW)*2
Rated
Current (A)
Overload
Pattern
1 820 500 600
  • 600A 10sec
    +300A 10sec (Charge)
  • 300A 30sec (Discharge)
2 820 1000 1200
  • 1200A, 10sec
    +600A, 10sec (Charge)
  • 600A, 30sec (Discharge)
  • *1 Initial charging and discharging voltage can be varied. (Options to control remotely or locally are available)
  • *2 Indicating basic pattern. Interval is 180 seconds per cycle.
DC1500V
No.Rated
Voltage (V)
Rated
Capacity (kW)
Equipment Configuration and Dimension (W x H x D :m)
I/ODCL
Panel
IGBT
Panel
DCL
Panel
Li-Battery
Panel
1 1650 500 1Unit
1.0 x 2.1 x 1.3
1Unit
1.8 x 2.1 x 1.3
1Unit
1.0 x 2.1 x 1.3
1Unit
2.5 x 2.3 x 1.2
2 1650 1000 1Unit
1.0 x 2.1 x 1.3
1Unit
1.8 x 2.1 x 1.3
1Unit
2.0 x 2.1 x 1.3
1Unit
5.0 x 2.3 x 1.2
3 1650 2000 1Unit
1.2 x 2.1 x 1.3
1Unit
2.5 x 2.1 x 1.3
1Unit
3.0 x 2.1 x 1.3
1Unit
10.0 x 2.3 x 1.2